Author Topic: Rotex 150 cutting out  (Read 1411 times)
0 Members and 1 Guest are viewing this topic.
RICHDEMPSEY

Offline Offline

Location: Inistioge Co Kilkenny Ireland
Member Since: Aug 2010
Posts: 9


« on: August 08, 2010, 12:35 PM »


Hi guys. First time poster, I just made my first Festool purchase, the Ro150 feq 110v, My problem is , i'm using it to sand douglas fir beams on site,powered by a generater 2.7 kva. The sander will run for about five seconds then cut out. Any thoughts or advice anybody?By the way, great forum
Logged
Festool USA does not pre-approve the contents of this website nor endorse the application or use of any Festool product in any way other than in the manner described in the Festool Instruction Manual. To reduce the risk of serious injury and/or damage to your Festool product, always read, understand and follow all warnings and instructions in your Festool product's Instruction Manual. Although Festool strives for accuracy in the website material, the website may contain inaccuracies. Festool makes no representations about the accuracy, reliability, completeness or timeliness of the material on this website or about the results to be obtained from using the website. Festool and its affiliates cannot be responsible for improper postings or your reliance on the website's material. Your use of any material contained on this website is entirely at your own risk. The content contained on this site is provided for informational purposes only and does not constitute professional advice.

Shane Holland
Festool USA Employee
FOG Administrator

Online Online

Location: USA
Member Since: Jan 2007
Posts: 5123



WWW
« Reply #1 on: August 08, 2010, 01:30 PM »

Rich, welcome to the forum.  Have you tested your Rotex connected to a regular electrical outlet to see if it exhibits the same problem?

If you don't get the problem resolved, I would recommend that you contact Festool Ireland:

TTS Tooltechnic Systems Ireland Ltd.
E12 Calmount Park Ballymount
Dublin 12
Ireland

phone: 00353(0) 1 8642240
fax: 00353 (0)1 8642247
sales@festool.ie

http://www.festool.ie
Logged

Shane Holland | Festool USA | Sales: 888-337-8600 | Service: 800-554-8741 | sho@festoolusa.com

Faster. Easier. Smarter.



Power Tools, Domino Joiners, RRP HEPA Vacs, Track SawsDrywall Sanders, Cordless Drills, Tools for Painters, LED Worklamp, Router Tables
RICHDEMPSEY

Offline Offline

Location: Inistioge Co Kilkenny Ireland
Member Since: Aug 2010
Posts: 9


« Reply #2 on: August 08, 2010, 01:50 PM »

Thanks Shane for such a quick reply, it works fine when connected to the mains.I think I might need a bigger generator
Logged
Rick Christopherson
Retailer

Offline Offline

Location: Central U.S.
Member Since: Jan 2007
Posts: 775



WWW
« Reply #3 on: August 08, 2010, 01:53 PM »

Rich,
That's a pretty small generator and outputs only 20 amps at 120 volts. Even though the sander doesn't draw any where near that load, it is very likely that the generator's output frequency (engine rpm) is fluctuating when the sander begins to draw power. I spoke with my contact in the service department about this topic recently, and even though we don't have a definitive answer, we suspect the electronic controls are shutting down the tool because it gets confused when it sees significant swings in the frequency. Line power (mains power for you European folks) will have very steady frequency, so the sander is expecting a constant frequency.

This is just a shot in the dark, but if you have a dust extractor, try turning this on to manual before starting the sander (plug the sander directly into the generator). The reasoning behind this is that if the generator is already partially loaded, the slight increase in load from the sander will not be quite as drastic. The generator's governor may be able to maintain engine speed better.
Logged

RICHDEMPSEY

Offline Offline

Location: Inistioge Co Kilkenny Ireland
Member Since: Aug 2010
Posts: 9


« Reply #4 on: August 08, 2010, 02:05 PM »

I have tried turning the tool down but to no effect, Shane. Rick I will try turning on a vacuum first and see how that goes.I really wish the electrical supply company in Ireland would give us a temporary supply when building on new sites like they used to in the good old USA.